# Battery materials research — coin cells & µA

> Materials research battery test configurations: µA-resolution cell testers, wide-range channels and AC internal resistance for coin cells.

Canonical: https://batteryxlab.com/industries/materials-research/
Language: en

- [Home](https://batteryxlab.com/)
- [Solutions](https://batteryxlab.com/solutions/)
- Materials research

![Close-up of cylindrical cells connected to a test channel module]()

Materials research

# Coin cells, microamp currents and reproducible screening

Materials screening compares nominally identical cells. The instrument has to resolve the difference between two materials without adding a difference of its own.

[Request a configuration](https://batteryxlab.com/contact/?bundle=materials-research)
[See solutions by role](https://batteryxlab.com/solutions/)

Test challenges

## What makes this application difficult

### The signal is small

Coin-cell leakage and low-rate cycling sit in the microamp range. A channel whose lowest range starts at 0.5 µA covers that work without adding a separate picoammeter and a second data stream.

### Contact resistance is part of the result

Coin-cell holders add resistance and a temperature gradient. Four-terminal sensing at the holder and a consistent assembly torque keep cell-to-cell comparisons meaningful.

### Temperature changes the ranking

Arrhenius behaviour means a 2 °C offset can reorder two candidate materials. Chamber stability and a recorded temperature channel belong to the method, not to the facilities checklist.

### Three cells are not statistics

Screening needs enough channels per variant to separate a real effect from assembly variance. Eight channels per unit, twenty units per rack, keeps a materials matrix inside one schedule.

Recommended configuration

## A configuration that works as a chain

Every model below is a published datasheet in the model library. Channel count, ranges and accuracy are read from that datasheet at build time, not retyped here.

Cell · BTS-4008Q

### [BTS-4008Q-5V100mA-124](https://batteryxlab.com/products/bts-4008q-5v100ma-124/)

Four current ranges from 0.5 µA to 100 mA, with 0.01% voltage accuracy. Eight channels per unit and up to twenty units per rack for parallel coin-cell screening.

Channels

8

Voltage

10mV~5V

Current ranges

R1: 0.5μA~0.1mA · R2: 0.1mA~1mA · R3: 1mA~10mA · R4: 10mA~100mA

Accuracy

V ±0.01% of FS · I ±0.02% of FS

Sampling

10Hz

Dimensions

483mm x 310mm x 48mm

[Open datasheet →](https://batteryxlab.com/products/bts-4008q-5v100ma-124/)

### [BTS-4008Q-5V6A-S1/164](https://batteryxlab.com/products/bts-4008q-5v6a-s1/)

0.5 mA to 6 A over four ranges for pouch and small cylindrical cells, using the same schedule format as the microamp unit.

Channels

8

Voltage

25mV~5V

Current ranges

R1: 0.5mA~100mA · R2: 100mA~500mA · R3: 500mA~3A · R4: 3A~6A

Accuracy

V ±0.02% of FS · I ±0.02% of FS

Sampling

10Hz

Dimensions

483mm x 404mm x 130mm

[Open datasheet →](https://batteryxlab.com/products/bts-4008q-5v6a-s1/)

### [BT-9562](https://batteryxlab.com/products/bt-9562/)

AC four-terminal internal resistance at 1 kHz, four ranges from 3.3 mΩ to 3.3 Ω, to separate electrode and electrolyte contributions from contact resistance.

Impedance ranges

-3.3~3.3mΩ · -33~33mΩ · -330~330mΩ · -3.3~3.3Ω

Impedance accuracy

±0.4% · ±0.3% · ±0.3% · ±0.3%

Test method

AC 4-terminal method (1kHz ±0.02Hz)

Dimensions

W220mm × H80mm × D300mm

Weight

2.5kg

Input power

45VA

[Open datasheet →](https://batteryxlab.com/products/bt-9562/)

## Typical sequence

- ### Electrode and slurry prep

Coating weight, calendering and punch diameter recorded per batch; the cell build is part of the experiment, not a prelude to it.

- ### Coin-cell assembly

Consistent separator, electrolyte volume and crimping torque; holders are mapped to channels before the first cycle.

- ### Formation

Low-rate first cycles with voltage limits and a recorded coulombic efficiency for every cell.

- ### Rate capability and impedance

Stepped C-rates at controlled temperature, then AC internal resistance on the same cells without remounting.

- ### Cycling and report

Long-term cycling at the chosen rate, with capacity, efficiency and DCIR exported per cell and per material variant.

## Records that survive an audit

A materials result has to survive review by someone who was not in the lab. Method, instrument and calibration need to be in the same record.

- BTS 9.1 stores the full schedule and measured values, with an audit trail for edits.

- CNAS calibration to ISO/IEC 17025 is issued per module and referenced in the method record.

- LIMS import and export keep cell ID, material variant and build batch together.

- Exports include the sampling rate and current range in use, so rate-dependent results can be interpreted.

## Delivery lead time

Working days from a confirmed order. The same table and conditions as the solutions page.

| Type | Mainland China | Overseas |
| --- | --- | --- |
| Standard products | **40 working days** | **80 working days** |
| Non-standard products | Standard lead time + 50% (i.e. 60 / 120 working days) | Same |

- Counted in working days; weekends and statutory holidays are not included.

- Counted from order confirmation and receipt of the advance payment.

- Sea or air freight and customs clearance are not included.

- The final lead time is confirmed in the quotation / contract.

## Related pages

- [Cell testers, microamp to 300 A](https://batteryxlab.com/cell-testers/)

- [Academic start kit](https://batteryxlab.com/solutions/#academic)

- [Materials QC bundle](https://batteryxlab.com/solutions/#materials-qc)

- [Solid-state and new chemistries](https://batteryxlab.com/applications/#solid-state)

## Set up a materials screen

Send the cell format, current range, channel count and temperature requirements. We reply with a configuration and the fixtures needed to make it repeatable.

[Request a configuration](https://batteryxlab.com/contact/?bundle=materials-research)
[See solutions by role](https://batteryxlab.com/solutions/)

## Contact

- Email: sales@batteryxlab.com
- Phone: +852 4436 9298
- WhatsApp: https://wa.me/85244369298
- Request a quote: https://batteryxlab.com/contact/
- Full site index for agents: https://batteryxlab.com/llms.txt