# Module & Pack Battery Test Systems to 1500 V

> Module and pack test systems to 1500 V / 1200 A with >90% regenerative feedback, CAN/SMBus BMS links and end-of-line routines.

Canonical: https://batteryxlab.com/module-pack/
Language: en

- [Home](https://batteryxlab.com/)
- Products
- Module & Pack

Max voltage
1500 V

Max current
1200 A

Energy feedback
>90%

Power factor
0.99

End-of-line test
EOL

BMS comms
CAN/SMBus

Typical values, model-dependent. Final specifications are confirmed at quotation.

Module & pack · up to 1500 V

# Module and pack test systems: high-voltage testing that gives the energy back.

Module and pack systems to 1500 V / 1200 A, with regenerative discharge that returns more than 90% of discharge energy to the grid.

BMS communication keeps the test inside the pack's own limits. Power factor is 0.99 — typical, model-dependent. End-of-line routines run from the same BTS 9.1 controller used for development cycling.

[Request a quote](https://batteryxlab.com/contact/)
[Download datasheets](#datasheets)

![Rows of NEWARE module test cabinets on a production floor]()

Module & pack

BTS-6000 cabinets on a production floor, configured per module format.

Selection guide

## Find the series that fits your test envelope

Give us the device, maximum voltage and maximum current. The recommendation stays inside the ranges published on this site — no invented models.

Device under test

CellModulePack

Maximum voltage (V)
Maximum current (A)
Channel count (optional)

Recommend a series

The selector uses published voltage and current classes: up to 15 V / 2000 A at cell level, 6–150 V / 300 A at module level and 150–1500 V / 1200 A at pack level. Channel count is confirmed at quotation.

### Published ranges at a glance

The selector is an interactive shortcut. Without JavaScript, use this table.

| Level | Series | Voltage | Current | Notes |
| --- | --- | --- | --- | --- |
| Cell | CT-4008Q | ≤ 15 V | ≤ 30 A | Four auto ranges |
| Cell, high current | CE-6000 / BTS-6008A | ≤ 150 V | ≤ 300 A | Eight channels per cabinet |
| Cell, precision | CT-9000 | ≤ 5 V | ≤ 15 A | µA class, 1000 Hz |
| Large cell | CTE-8000 | ≤ 5 V | ≤ 2000 A | Energy recovery |
| Module | CE-6000 | ≤ 150 V | ≤ 300 A | BMS communication |
| Pack | CE-7000 / BTS-6000-IGBT | ≤ 1500 V | ≤ 1200 A | Energy recovery |

Typical classes, model-dependent. Final ratings, channel count and options are confirmed at quotation.

Recommended series

### CT-4008Q

Cell level, up to 30 A: the four-range CT-4008Q channel covers the envelope with one wiring setup.

[View series](https://batteryxlab.com/cell-testers/)
[Talk to an engineer](https://batteryxlab.com/contact/)

[Download the series datasheet](https://batteryxlab.com/resources/#datasheets)

Recommended series

### CT-9000

Cell level and below 1 A: the CT-9000 µA-class channel adds the precision and 1000 Hz sampling this envelope needs.

[View series](https://batteryxlab.com/cell-testers/)
[Talk to an engineer](https://batteryxlab.com/contact/)

[Download the series datasheet](https://batteryxlab.com/resources/#datasheets)

Recommended series

### CTE-8000

Large-format cell above 300 A: the CTE-8000 regenerative channel is the published fit for this current.

[View series](https://batteryxlab.com/cell-testers/)
[Talk to an engineer](https://batteryxlab.com/contact/)

[Download the series datasheet](https://batteryxlab.com/resources/#datasheets)

Recommended series

### CE-6000

Module level, 6–150 V, and the 5 V high-current class up to 300 A (BTS-6008A): CE-6000 pairs regenerative power stages with BMS communication.

[View series](https://batteryxlab.com/module-pack/)
[Talk to an engineer](https://batteryxlab.com/contact/)

[Download the series datasheet](https://batteryxlab.com/resources/#datasheets)

Recommended series

### CE-7000 / BTS-6000-IGBT

Pack level, 150–1500 V: CE-7000 / BTS-6000-IGBT cover full-pack cycling with energy recovery.

[View series](https://batteryxlab.com/module-pack/)
[Talk to an engineer](https://batteryxlab.com/contact/)

[Download the series datasheet](https://batteryxlab.com/resources/#datasheets)

### No recommendation yet

Enter maximum voltage and current to see a series.

[Talk to an engineer](https://batteryxlab.com/contact/)

### Outside the published sample range

That voltage or current is outside the published ranges (up to 1500 V; up to 2000 A at cell level or 300 A at module level or 1200 A at pack level). Contact an engineer and we will confirm a configuration instead of guessing.

[Talk to an engineer](https://batteryxlab.com/contact/)

By application

## Start from the test, not the model

Three common starting points. Each card names the series we would shortlist and the published figures that decide the fit.

[### Modules and end-of-line Module cycling and end-of-line routines where the pack stays under 150 V and the line needs pass/fail results. Recommended series **CE-6000** Voltage 60–150 V Current ≤ 200 A Energy feedback >90% Jump to specifications](#published-specs)
[### Packs and energy storage Full-pack cycling for ESS and EV packs, with BMS communication and discharge energy returned to the grid. Recommended series **CE-7000 / BTS-6000-IGBT** Voltage 150–1500 V Current 100–1200 A Energy feedback >90% Jump to specifications](#published-specs)
[### High voltage, high current High-voltage pack testing at full current, where the 1500 V class and 1200 A are both needed. Recommended series **BTS-6000-IGBT** Voltage 300–1500 V Current 100–1200 A BMS comms CAN / SMBus Jump to specifications](#published-specs)

![Module test system]()

CE-6000 module test system — regenerative power stages with BMS communication in the same cabinet.

![Module test cabinet]()

Cabinet arrangement: power modules and control electronics are separated for service access.

![Module test system cabinet]()

Module test system cabinet

![Module and pack test cabinet]()

Module and pack test cabinet

![Module test rack]()

Module test rack

Test profiles

## What a typical week looks like

Representative profiles for the tests this platform is bought to run. Rates are C-rates; durations are typical and depend on cell capacity, cooling and limits.

| Test | Typical profile | Rate | Duration |
| --- | --- | --- | --- |
| Capacity | 0.5C CC-CV charge, 0.5C discharge | 0.5C | 6–10 h |
| Cycle life | 1C/1C continuous cycling at 25 °C | 1C | 1,000–5,000 cycles |
| DCIR | 10 s 1C pulse, 10 s rest | 1C | 90%, pack level

- Power factor: 0.99

- BMS comms: CAN / SMBus / CAN-FD / DBC

- End-of-line test: EOL routines

- Software: BTS 9.1

- Data path: LIMS-friendly export

Company-reported and typical. Voltage, current and feedback figures vary by model and are confirmed at quotation.

### Discharge energy returns to the grid

Instead of burning discharge energy as heat, the power stage converts it back to mains. The result is lower heat load and a lower energy bill per test hour.

Schematic. Paths are simplified; feedback figures are typical, model-dependent.

## Classes by voltage and current

Pick the voltage class that matches the device under test, then the current your profile needs. Final ratings are set at quotation.

| Model (class) | Max voltage | Max current | Energy feedback | BMS comms | Typical use |
| --- | --- | --- | --- | --- | --- |
| Module class (60 / 120 V) | 60 / 120 V | Specify at quotation | >90% | CAN / SMBus | Module and string cycling |
| Pack class (1500 V) | 1500 V | 1200 A | >90% | CAN / SMBus / CAN-FD | Full-pack cycling, drive-cycle profiles |
| Pack EOL class (1500 V) | 1500 V | 1200 A | >90% | CAN / SMBus / CAN-FD | End-of-line pass/fail routines |

Tiers are indicative. Ratings are typical, model-dependent. Part numbers are confirmed at quotation.

[5000 Series SMBus →](https://batteryxlab.com/5000-series/)

### 6000 platform — 2,694 buildable configurations

One platform, four classes: 5 V/6 V cell channels up to 2,400 A; 20–200 V module channels up to 1,200 A; 150–3,000 V pack cabinets up to 2,400 kW; and EOL stations at 100/200 V. 8-channel parallel on cell/module, 4-channel parallel on pack. Up to 96% efficiency with SiC, power factor ≥99%, THDi ≤5%.

- Voltage span: 5 V–3,000 V

- Current span: 50–2,400 A

- Channels: 1–96 ch

- Buildable configurations: 2,694 configs

- Efficiency: 96% SiC

- Sampling: 100 Hz

![BTS-6000 cell test system]()

Pack naming and the CE-6000 / CE-7000 boundary are being confirmed; existing CE-7000 / BTS-6000-IGBT pages remain the pack reference.

### What a pack test line includes

A complete line is more than a power cabinet. These are the elements we configure together; the exact mix is set at quotation.

| Element | Typical specification | Notes |
| --- | --- | --- |
| Power cabinets | 1–6 cabinets per station | Parallel cabinets raise current; each cabinet keeps its own protection. |
| Voltage / current class | 100 V module class or 1500 V pack class | Current rating depends on the profile, not only the pack capacity. |
| BMS interface | CAN, SMBus, CAN-FD; DBC import | Pack communication specification is required before quotation. |
| Fixtures and cabling | Busbar, lug or custom harness | Supplied to the pack terminal geometry; high-voltage interlocks included. |
| Safety | Contactors, insulation monitoring, emergency stop | Integrated with the test controller; site-specific rules apply. |
| Software | BTS 9.1 with EOL routines | Schedules, limits, pass/fail records and LIMS-friendly export. |

Illustrative configuration. Channel and cabinet counts, fixtures and interfaces are confirmed at quotation.

## What this system does not do

Clear boundaries make a proposal easier to trust. If your test needs one of these, say so and we will scope it separately.

- It is not an abuse-test stand. Nail penetration, crush and overcharge-to-thermal-runaway require a dedicated safety enclosure and gas handling.

- It does not replace an environmental chamber. Temperature and humidity control is a separate chamber or an all-in-one configuration.

- It does not design or emulate a BMS. It communicates with the pack BMS using the protocol you provide.

- It does not issue regulatory pass certificates. EOL limits and reports are user-defined; homologation testing stays with an accredited test house.

- Its measurement class is aimed at pack-level energy and power, not at µA leakage. Use a cell tester for cell-level precision work.

- It does not include site power distribution or civil works. Those are specified with your facilities team.

### Module and pack documentation

Pack-system datasheets are configuration-specific: voltage class, current, BMS interface and cabinet count change the specification. The shared measurement-platform datasheets are in the resources centre; request the pack sheet for your configuration.

[Open the resources centre](https://batteryxlab.com/resources/)
[Request a pack datasheet](https://batteryxlab.com/contact/)

## Sizing the system

**Module or full pack?**

Start from the highest voltage you will test. Module work usually stops well below 100 V; full packs need the 1500 V class. Current, cabling and BMS interface follow from the pack specification and are confirmed at quotation.

**What does energy feedback change?**

Regenerative discharge returns more than 90% of discharge energy to the grid instead of dissipating it as heat. Over a production line running continuous cycles, that changes both the energy bill and the cooling load. Typical, model-dependent.

**Which BMS protocols are supported?**

CAN, SMBus, CAN-FD and DBC-described messages. Send the pack's communication specification with your enquiry so the interface and message set can be confirmed before quotation.

**Can one system test 400 V and 800 V packs?**

Yes. A 1500 V class system covers both, provided the current rating suits the profile. The voltage window and current are configured per project; do not size the system from pack nominal voltage alone.

**How does end-of-line testing fit?**

EOL routines run on the same BTS 9.1 controller as development cycling, with limits and pass/fail results recorded per pack. A separate EOL station is not required unless the line layout calls for one.

**What do you need to quote a line?**

Pack voltage range, maximum charge and discharge current, the test profile, BMS protocol and connector details, station count and the site's power available. With those, we can return a configured proposal and an energy-feedback estimate.

### Range, accuracy and sampling

Company-published typical values for the main series. The exact model and option set are confirmed at quotation.

Tick two or three models, then compare their published figures.

Up to 3 models. Clear one to add another.

Compare selected

[See all 36 models →](https://batteryxlab.com/products/)

| Series / model | Voltage | Current | Accuracy | Sampling / response | Typical use |
| --- | --- | --- | --- | --- | --- |
| BTS-5008 — consumer module | 20 / 30 V | 10–15 A | V ±0.02% FS | Confirm at quotation | Small modules and packs |
| CE-6012 — module | 60 / 120 V | 50 / 100 / 200 A, 8–12 ch | V ±(0.02% FS + 0.02% RD) · I ±(0.05% FS + 0.05% RD) | Confirm at quotation | Module cycling |
| CE-7000 — pack | 60–1000 V | 100–1000 A; 75–600 kVA | ±0.1% FS | Confirm at quotation | Pack cycling; >90% energy recovery |
| BTS-6000-IGBT — HV pack | 300–1500 V | 100–1200 A | Confirm at quotation | Confirm at quotation | High-voltage pack testing |

Values are typical and company-published. Accuracy is stated as % FS unless shown otherwise. Confirm the final model, range and option at quotation.

NEWARE Technology

### Model comparison

Clear
Print comparison

### Spec a module or pack test line

Send the pack voltage, current profile, BMS protocol and station count. We return a configured proposal with energy-feedback estimates, lead time and service options. We reply typically within one business day.

[Talk to an engineer](https://batteryxlab.com/contact/)
[See EV applications](https://batteryxlab.com/applications/#ev)

## Related pages

- [EV pack testing](https://batteryxlab.com/applications/#ev)
- [Energy-storage testing](https://batteryxlab.com/applications/#energy-storage)
- [Fast-charge testing](https://batteryxlab.com/applications/#fast-charge)

- [See all 36 models →](https://batteryxlab.com/products/)

- [All 52 peer-reviewed papers](https://batteryxlab.com/publications/)

## Research citing this instrument family

- [Metal-Dependent Lithiation Behaviors in Cobalt and Zinc Metal–Organic Frameworks as Lithium-Ion Battery Anodes](https://doi.org/10.1021/acs.inorgchem.5c06095) — Tungad (2026), Inorganic Chemistry
- [Surface engineering enables robust SEI growth towards a stable and efficient lithium-ion battery SiO x anode](https://doi.org/10.1039/d5ra08407e) — Wu (2026), RSC Advances
- [Electronic structure formed by Y₂O₃-doping in lithium position assists improvement of charging-voltage for high-nickel cathodes](https://doi.org/10.1038/s41467-024-52768-7) — Wang (2025), Nature Communications

## Contact

- Email: sales@batteryxlab.com
- Phone: +852 4436 9298
- WhatsApp: https://wa.me/85244369298
- Request a quote: https://batteryxlab.com/contact/
- Full site index for agents: https://batteryxlab.com/llms.txt