Channels 8
Voltage 5–30 V
Current 10–30 A
Sampling 100 Hz
Protocol SMBus / I2C · SBS 1.1
Offline storage 1 GB / channel

Typical values, model-dependent. Final specifications are confirmed at quotation.

5000 Series · SMBus / SBS 1.1

5000 Series — SMBus battery testers for smart battery packs

Most testers only see the terminals. The 5000 Series also talks to the battery. Native SMBus/I2C support reads SBS 1.1 data — state of charge, cycle count, protection flags, temperature — and binds it to the charge/discharge record on the same time axis.

Eight independent channels, 5–30 V, 10–30 A, 100 Hz sampling. Built for 3C packs, BMS validation and smart-battery production tests.

Models

Six models for 3C packs

All models provide eight independent channels. Choose the voltage and current class that covers the pack, then confirm the cable set at quotation.

5000 Series models by voltage, current and accuracy
Model Voltage Current Channels Power/ch V accuracy I accuracy Response
CE-5008-5V30A-SMB2.5–5 V (discharge)3 mA–30 A8150 W±0.02% range±0.03% range≤2 ms
CE-5008-20V10A-SMB2.0–20 V10 mA–10 A8200 W±0.02% range±0.03% range≤20 ms
CE-5008-20V15A-SMB2.5–20 V15 mA–15 A8300 W±0.02% range±0.03% range≤20 ms
CE-5008-20V20A2.5–20 V20 mA–20 A8400 W±0.02% range±0.03% range≤30 ms
CE-5008-30V10A-SMB3–30 V10 mA–10 A8300 W±0.02% range±0.03% range≤20 ms
CE-5040-20V10A-SMB2.0–20 V10 mA–10 A8200 W±0.02% range±0.02% range≤20 ms

CE-5008-20V20A uses the same channel platform without SMBus; confirm the protocol at quotation.

Specifications are for the listed model. Accuracy is stated as a percentage of range. Final configuration and part numbers are confirmed at quotation.

SMBus / SBS

What the tester reads from the battery

The communication record is logged alongside voltage, current and capacity, so pack state and electrical behaviour can be compared on one timeline.

SBS 1.1 dataState of charge, remaining capacity, full-charge capacity, cycle count, temperature, voltage, current, protection flags
SMBus / I2C100 kHz SMBus/I2C; SDA/SCL pull-ups; 8 channels independent
Refresh>10 Hz with a small parameter set; data is time-aligned with the charge/discharge record
BoundaryNot for 1 kHz transients (9000 Series) or packs above 30 A (6000 Series)

SBS register coverage and refresh rate depend on the pack's BMS and the selected parameter set. Confirm the register map with your pack specification.

Applications

Where the 5000 Series fits

Phone / notebook packs

CE-5008-20V10A-SMB

Power tools / drones

CE-5008-5V30A-SMB

30 V packs

CE-5008-30V10A-SMB

Multi-string packs ≤20 V

CE-5008-20V20A

Testing a smart battery?

Send the pack voltage, capacity and SBS spec — we will confirm the channel configuration and cable set.

Talk to an engineer

Request a quote