Resources · Technical notes

Technical notes

Application notes for engineers who run the tests: range selection, pulse timing, sampling, formation pressure, chamber temperature, BMS communication, data integrity, round-trip efficiency and safety interlocks. Each note states the published parameter behind the recommendation and separates it from our engineering judgement.

Technical notes are published in English. Product pages, datasheets and quotations are available in all six site languages.

Safety

Safety interlocks: layers and proof tests

Overvoltage, overcurrent, overtemperature, door and E-stop belong to different layers. How to design the chain and the checks test plans usually miss.

· 8 min read

Read note →
MeasurementThermal

Fixture contact resistance and cycle data

Four-wire sensing does not remove the contact. Where to place the sense tips, what 1 mΩ costs at 100 A, and how to verify a fixture.

· 5 min read

Read note →
ThermalService

Round-trip efficiency: cell, tester, facility

Round-trip efficiency is three efficiencies stacked. How to measure the cell term, where the rest goes, and why one point matters over a cycle life.

· 7 min read

Read note →
MeasurementService

Cycle data: sampling, storage, audit trail

A 100 Hz record is not free. How to choose a rate per test, keep the raw data intact, and hand a defensible record to the LIMS.

· 8 min read

Read note →
Service

Calibration intervals and ISO 17025

How to read a calibration certificate, compare uncertainty with tolerance, and set an interval that survives an audit.

· 5 min read

Read note →
Measurement

BMS communication: CAN and CAN-FD records

Channel data shows what the tester did. BMS frames show what the pack thought. DBC mapping, DTCs, HVIL and a shared time base.

· 8 min read

Read note →
ThermalService

Energy recovery economics for cycling

What >90% regenerative feedback does and does not cover, and how to build a payback calculation from your own throughput and tariff.

· 5 min read

Read note →
Thermal

Chamber uniformity: what ±0.5 °C means

The two numbers on a chamber datasheet measure different things. How to read them, place sensors, and test the chamber under a real cell load.

· 8 min read

Read note →
Measurement

Negative-pressure formation and the cell

Why formation fixtures pull a vacuum, how stack pressure and gas removal affect SEI and lithium plating, and how to prove equal pressure on every channel.

· 8 min read

Read note →
Measurement

Sampling rate and HPPC: what 10 Hz hides

The difference between 10 Hz, 100 Hz and 1000 Hz is not file size. It is which part of a pulse, and which dQ/dV feature, survives the record.

· 5 min read

Read note →
Measurement

DCIR pulse timing: where the numbers come from

Current response, sampling interval and range selection decide whether a DCIR value is reproducible. A timing budget for 10 ms and 10 s measurements.

· 5 min read

Read note →
RangeMeasurement

Reading microamp leakage on a 300 A channel

A 300 A range cannot resolve microamps. How to route a leakage step to a channel that can, and what to record when it gets there.

· 5 min read

Read note →

RSS feed · Datasheets and glossary

Talk to an engineer

Request a quote