9000 Series · Precision cell testers
9000 Series — precision micro-current cell testers
The 9000 Series is the 0–5 V precision tier of the cell-tester range: 0.1 µA-class current resolution, 1 kHz sampling and ≤100 µs response, for materials research, coin cells, SEI formation and solid-state electrolytes.
Five models span 2–8 channels and 5–15 A. They share the same measurement front end — low-noise amplification, four current ranges per channel and a response fast enough to catch early-cycle transients.
Models
Five models, one measurement front end
Voltage is 0–5 V on every model. Channel count, current range and per-channel power are the variables.
| Model | Channels | Voltage | Current ranges | Power per channel | Sampling | Response | Note |
|---|---|---|---|---|---|---|---|
| CT-9008-5V12A-SMB | 8 | 0 – 5 V | 0.12 mA – 12 A (4 ranges) | 60 W | 1 kHz | ≤100 µs | — |
| CT-9008-5V6.5A-SMB | 8 | 0 – 5 V | 0.1 µA – 6.5 A (4 ranges) | 32.5 W | 1 kHz | ≤100 µs | — |
| CT-9002-5V6A-204n | 2 | 0 – 5 V | 0.1 µA – 6 A (4 ranges) | 30 W | 1 kHz | ≤100 µs | — |
| CT-9004-5V5A | 4 | 0 – 5 V | 0.1 µA – 5 A (4 ranges) | 25 W | 1 kHz | ≤100 µs | — |
| CT-9008-5V15A | 8 | 0 – 5 V | 0.015 A / 0.15 A / 1.5 A / 15 A (4 ranges) | 75 W | 1 kHz | ≤350 µs | Three-phase 380 V supply |
Specifications are reproduced from the model table as published. Final configuration and part numbers are confirmed at quotation.
Why a separate platform
Below 1 mA, the bench is part of the measurement
At 0.1 µA, the current a general-purpose cycler treats as noise is the signal. The 9000 Series front end is designed around that floor: lower-noise amplification and four auto-switched current ranges, with sampling fast enough to separate the measurement from the electrical environment it sits in.
Range switching matters more here than it does at 30 A. A µA-range test that autoranges mid-step changes the effective gain and can put a step in the data. The 9000 Series keeps range switching tied to the test step and logged, so a cycle trace stays comparable across ranges. Cables and fixtures are the last metre of the same problem — shielded leads and short, fixed four-terminal paths keep the floor where the specification says it is, which is why the series is specified for coin cells, SEI formation and solid-state electrolytes.
Where it fits
9000 vs 4000 and 8000
The 4000 Series is the general cell cycler — broad voltage and current envelopes at 10 Hz sampling, for everyday cycling and production. The 8000 Series covers in-situ channels and higher-current cell testing. The 9000 Series is the precision tier of the same catalogue: choose it when the experiment is noise-limited rather than power-limited.
Specifying a µA-class test?
Send the current range, channel count and fixture type. We will confirm the 9000 Series configuration and cable set against your cells.