9000 Series · Precision cell testers

9000 Series — precision micro-current cell testers

The 9000 Series is the 0–5 V precision tier of the cell-tester range: 0.1 µA-class current resolution, 1 kHz sampling and ≤100 µs response, for materials research, coin cells, SEI formation and solid-state electrolytes.

Five models span 2–8 channels and 5–15 A. They share the same measurement front end — low-noise amplification, four current ranges per channel and a response fast enough to catch early-cycle transients.

Models

Five models, one measurement front end

Voltage is 0–5 V on every model. Channel count, current range and per-channel power are the variables.

9000 Series models — channels, voltage, current ranges, power, sampling and response
Model Channels Voltage Current ranges Power per channel Sampling Response Note
CT-9008-5V12A-SMB 8 0 – 5 V 0.12 mA – 12 A (4 ranges) 60 W 1 kHz ≤100 µs —
CT-9008-5V6.5A-SMB 8 0 – 5 V 0.1 µA – 6.5 A (4 ranges) 32.5 W 1 kHz ≤100 µs —
CT-9002-5V6A-204n 2 0 – 5 V 0.1 µA – 6 A (4 ranges) 30 W 1 kHz ≤100 µs —
CT-9004-5V5A 4 0 – 5 V 0.1 µA – 5 A (4 ranges) 25 W 1 kHz ≤100 µs —
CT-9008-5V15A 8 0 – 5 V 0.015 A / 0.15 A / 1.5 A / 15 A (4 ranges) 75 W 1 kHz ≤350 µs Three-phase 380 V supply

Specifications are reproduced from the model table as published. Final configuration and part numbers are confirmed at quotation.

Why a separate platform

Below 1 mA, the bench is part of the measurement

At 0.1 µA, the current a general-purpose cycler treats as noise is the signal. The 9000 Series front end is designed around that floor: lower-noise amplification and four auto-switched current ranges, with sampling fast enough to separate the measurement from the electrical environment it sits in.

Range switching matters more here than it does at 30 A. A µA-range test that autoranges mid-step changes the effective gain and can put a step in the data. The 9000 Series keeps range switching tied to the test step and logged, so a cycle trace stays comparable across ranges. Cables and fixtures are the last metre of the same problem — shielded leads and short, fixed four-terminal paths keep the floor where the specification says it is, which is why the series is specified for coin cells, SEI formation and solid-state electrolytes.

Where it fits

9000 vs 4000 and 8000

The 4000 Series is the general cell cycler — broad voltage and current envelopes at 10 Hz sampling, for everyday cycling and production. The 8000 Series covers in-situ channels and higher-current cell testing. The 9000 Series is the precision tier of the same catalogue: choose it when the experiment is noise-limited rather than power-limited.

Specifying a µA-class test?

Send the current range, channel count and fixture type. We will confirm the 9000 Series configuration and cable set against your cells.

Talk to an engineer

Request a quote